Home and Garden Guidebook

Showing posts with label electrical appliances. Show all posts
Showing posts with label electrical appliances. Show all posts

Tuesday, 17 November 2026

How to Wire a Plug Safely: 9 Steps (With Pictures)

Open white UK plug showing three wires connected to brass terminals and a white ceramic fuse labelled BS 1362
How to wire a plug. This is a UK style, BS1363 plug with integral 13 amp fuse.
© Eugene Brennan

How to Wire a UK Plug

This guide shows you how to specifically wire a UK plug to a domestic appliance. However, the same basic principles of wiring a BS1363 type plug can be applied to plugs from other countries, the main difference being that the colour-coding of wiring is different.
The first section of the guide covers some background information on the various components of a plug and an explanation of fuses, which is worth reading before making connections. Scroll down past it to "Tools Required", for the guide to wiring.

British BS1363 Standard Plug (Type G Plug)

The BS1363 standard 3-pin plug is used in the UK (England, Wales, Scotland and Northern Ireland), the Republic of Ireland, Malaysia, Saudi Arabia, Cyprus, Malta and several other countries. It's categorised as plug type G by the International Electrotechnical Commission. The plug incorporates several safety features, including a fuse to protect the power cord and equipment. It also has shrouded pins to prevent inadvertent finger contact with the live or neutral pins during insertion and removal. By law in the EU, new appliances must be fitted with a plug, however, you may occasionally need to fit a plug to an older appliance.

The Safest Plug in the World?

The BS1363 Plug is undoubtedly the safest plug in the world and has the following features:

  • Fused: The primary function of the fuse is to protect the power cord/flex from overheating and possibly catching fire. The fuse will blow instantly when large short circuit currents are drawn and also when more moderate overloads occur.
  • Insulated Pins: This protects inadvertent contact with live pins during insertion and removal of the plug.
  • Shuttered Outlets on Sockets: This prevents children from inserting pins, nails or other metal items into socket outlets.
  • Polarized: The plug cannot be inserted upside down, reversing the live and neutral.
  • Long Earth Pin: This ensures that appliances are earthed during plug insertion, before the two power pins make contact.
  • Grips: These are at the edges of the plug to facilitate easier removal.
  • The Flex: This exits from the bottom of the plug to discourage removal by pulling on the flex.
Two side-by-side views of a white 3-pin UK plug held in a hand, front showing brass pins and back showing fuse label
3-Pin BS1363 Plug as used in the UK and Ireland. The black plastic shrouds surrounding half the pins prevent finger contact with the pins and potential shock during insertion and removal.
© Eugene Brennan

Parts of a Power Plug

Screw terminals are provided inside a plug for connection of the wires of a power cord (flex). A UK plug has 3 square pins, live, neutral and earth as shown below. The terminals are clearly marked with the letters "L", "N" and "E".

Live and Neutral Pins

These 2 pins carry power to the appliance.

Earth Pin

Under normal conditions, no current flows through this pin. However in the event of a fault in an appliance causing the metal casing to become live, this pin acts as a "bypass", shunting current away from the user. This trips the RCD and/or MCB at the electrical panel, shutting off power. The fuse in the plug may also blow (although the RCD may trip before this occurs). The earth pin also pushes open the safety shutters covering the live and neutral entry holes in a socket outlet when the plug is inserted.

When wiring a plug, it is essential to tighten the screws firmly down onto the bared wires of each conductor. This prevents arcing, overheating and potential fire.

Open white UK plug held in a hand with yellow arrows pointing to labelled terminals, fuse and strain relief
Live, neutral and earth terminals in a plug are marked L, N and E respectively
© Eugene Brennan

Fuse

A BS1363 plug is also fitted as standard with a ceramic, high breaking capacity (HBC) BS1362 fuse. Its primary function is to protect the power cord from overheating caused by current overloads due to a fault or a consumer drawing too much current (e.g., connecting too many high powered appliances to an extension lead or socket strip). The fuse may also protect an appliance's internal wiring/electronics, but additional fusing is often present in the appliance to cater for this scenario. Plugs are usually supplied as standard with a 13A fuse. This is the maximum current that the plug can supply, and if an appliance tries to draw in excess of this current, the fuse will eventually blow. Fuses don't instantly blow once their current rating is exceeded. Instead they have a characteristic such that large overloads (e.g., due to a short circuit, potentially drawing hundreds or thousands of amps from the distribution transformer) will cause the fuse to blow in fractions of a second, whereas small over currents could take minutes to blow the fuse. BS1362 specifies that the non-fusing current a fuse can carry is 1.6 times the rated current and the fuse must be able to carry this current for 30 minutes. Also the fusing current is 1.9 times the rated current and the fuse must blow within 30 minutes at this current.
13A is equivalent to a load of almost 3kW at 230 volts, 50 Hertz (Hz), the EU standardised voltage and frequency.

WARNING !!!

Fuses should be replaced by BS1362 standard ceramic types. These fuses have a ceramic body which can withstand the likely high current (potentially > 1000A in the case of a short circuit) and energy dissipated as heat inside the fuse when it blows as the result of an overload. Fuses shouldn't be replaced by types with glass bodies which can rupture.


If a lower powered appliance is connected to a plug, the fuse should be replaced by a lower rating fuse to suit the cord and appliance. 3A and 5A fuses are widely available.

Cord Grip

A strain relief clamp, also called a cord grip is provided. This must be screwed down onto the outer sheath or insulation of a cable, not the inner cores. Strain relief prevents tension on the cord during normal use from pulling wires out of the screw terminals.

Tools Required

You will need:

  1. A flat bladed screwdriver. A phase tester is ideal and is a useful tool to have in your home toolbox. It has an internal neon bulb which can be used for detecting the presence of high voltage at socket or lighting outlets.
  2. A wire snips (side cutters). You could also probably use a scissors.
  3. A sharp knife.
STOP !!!

If you don't feel confident about doing this, then don't do it!!!

If you get the wire colours mixed up, and connect them to the wrong terminals, the appliance may not work, or worse still, electrocute you or someone else.

Hand holding orange side cutters, clear screwdriver and grey utility knife against a grass background
Snips, screwdriver and knife
© Eugene Brennan

Wiring Procedure

Follow these steps to wire a plug after you unscrew and remove the cover (held by a single screw at the back)

Step 1: Remove the Outer Sheath of the Power Cord

About 5cm or 2 inches of the sheath (the outer mechanical protection of the power cord) must be removed. It's very important not to damage the insulation of the inner cores. You can snip down along the sheath if you have a snipe nose snips, alternatively score the sheath with the knife. Again you must be careful not to cut right through.

Open white UK plug with white flex inserted and a red arrow marking the cut line on the outer sheath
Sheath of power cord needs to be removed
© Eugene Brennan
Close-up of black side cutters cutting into the white outer sheath of a power cord
One way to remove the sheath is to snip down along the cable......
© Eugene Brennan
Close-up of a utility knife blade scoring the white outer sheath of a power cord
.........alternatively, score the outer sheath with a knife, taking care not to cut all the way through
© Eugene Brennan
Hands bending a white power cord to open a scored cut in the outer sheath
Bending the flex all round should break or weaken the sheath.
© Eugene Brennan
Hands pulling the white outer sheath off a power cord to reveal blue, green and brown inner wires
Pull off the section of sheath
© Eugene Brennan

Wire Colours in a Power Flex

Power flexes (or cords) have either two or three separate wires or cores inside: Live (brown) and neutral (blue) carry power to an appliance. The earth core (green/yellow) doesn't carry any current under normal circumstances and is used for safety reasons. The table below shows current and older wiring colours.

Colour comparison table showing current brown/blue/green-yellow wiring colours versus old red/black/green colours
New and older wiring colours in the UK and the EU.
© Eugene Brennan
Three-core white power flex with sheath stripped, brown live, green-yellow earth and blue neutral wires labelled
Plug wiring colours for a three core flex. Live is brown, neutral is blue and earth is green/yellow.
© Eugene Brennan

What If the Flex Only Has a Brown and Blue Wire? Double insulated Appliances

Metal-cased appliances normally have a three core flex attached. However, some appliances either have plastic, non-conductive casings or are doubly insulated. A double insulated appliance has a casing which, although it may still be metal, is sufficiently separated and insulated from internal live parts that there is no danger of it becoming live. These appliances are not earthed and only have a brown and blue core in their flex, i.e., no earth. (You can read an explanation of why earthing is needed in my guide "What is the Ground (Earth) Wire For?")
Double-insulated appliances are either marked "double insulated" or more usually the symbol below is printed on the info label.

Black double square symbol on white background with the words Double Insulated Symbol above it
Double insulated appliances are marked with this symbol.
© Eugene Brennan

Step 2: Shorten the Live (Brown) Wire and Neutral (Blue) Wires

The earth wire should be left long so that it's slack once the plug is wired. This caters for a scenario where the strain relieve isn't fully tightened. If the live or neutral wires are loose and the earth wire has no slack, it could potentially pull out of the terminal, leaving the neutral and/or live still connected. This would go unnoticed and the appliance could still work, but it would be unearthed, resulting in a shock hazard if a live to earth fault occured.

Open white UK plug with side cutters trimming the brown live wire while other wires remain longer
© Eugene Brennan

Step 3: Remove the Insulation from the Inner Cores

Remove the insulation from each conductor or core of the flex, about 12mm or just less than half an inch should be fine. You can either do this with a knife or use the snips. A snips is perfectly good as a wire stripper. With a bit of practice, all you need to do is grip the conductor, while cutting slightly through the insulation, and pull. Try this on some scrap flex first. Whichever way you bare the insulation, it's important to avoid breaking any strands of the copper conductor.

Close-up of side cutters stripping the green insulation from an earth wire of a three-core flex
Use a knife, wire strippers or snips to strip about 12mm of insulation
© Eugene Brennan
Three-core flex with insulation removed from the ends of brown, blue and green wires revealing copper strands
Bared conductors
© Eugene Brennan

Step 4: Twist the Strands and Double Them Over

Twist the strands of each core of the flex and double them over. This keeps them together and stops them spreading out when the terminal screws are tightened. Doubling over the ends also ensures the screw has more wire to tighten down on. This is particularly important if the flex is light gauge, in which case the screw may push the conductor out of the way as it is tightened, and only catch the edge of it.

Three-core flex with the copper strands of each wire twisted tightly together
Twist the stranded copper wire
© Eugene Brennan
Three-core flex with the ends of the twisted copper conductors folded back on themselves
Double over the ends of the wire
© Eugene Brennan

Choosing a Snips

Side cutters are available for cutting varying gages of cable. I have used an Xcelite side cutters, available from Amazon UK for over twenty years. The high mechanical advantage of long handles and short jaws means that they can easily snip through light to medium gage wire used in electronics. Jaws are closely spaced when closed and this is important for cleanly cutting very fine wire.

Blue-handled Xcelite 170M side cutters shown against a plain white background
Side cutters (wire snips)
Amazon

Step 5: Loosen the Screws on the Strain Relief (Cable Grip)

Hand holding a white UK plug while a green-handled screwdriver turns a strain-relief screw on the back
The strain relief on the plug is held by two screws
© Eugene Brennan
Plain text reminder listing brown to Live, blue to Neutral and green-yellow to Earth terminals
© Eugene Brennan

Step 6: Feed the Brown Wire into the L (Live) Terminal

Open white UK plug with the brown live wire inserted into the Live terminal after fuse removal
Feed the flex underneath the strain relief and push the strands of the brown wire into the terminal. It is easier to do this if you remove the fuse and terminal from the plug
© Eugene Brennan

Step 7: Connect the Green/Yellow Earth Wire into the E (Earth) terminal

Close-up of the green-yellow earth wire pushed into the brass Earth terminal of an open UK plug
Some appliances don't have an earth wire in their flex
© Eugene Brennan
WARNING !!!

Feed the wires all the way into the screw terminals and tighten securely.
Loose wires can cause arcing, overheating and potentially a fire!
Make Sure the Wires Are Caught by the Screw.

Close-up of a brass terminal screw tightened onto the doubled copper strands of a wire inside a UK plug
To avoid arcing, overheating, and in extreme cases a potential fire, it's essential to tighten screws.
© Eugene Brennan

Step 8: Finally Connect the Blue Wire to the N (Neutral) Terminal

Fully wired open white UK plug with all three wires connected and a red arrow pointing to the strain-relief clamp
Full wired plug - Make sure all the wires are neatly packed away so that they don't get caught by the cover or the cover fixing screw
© Eugene Brennan

Step 9: Tighten the Strain Relief and Replace the Cover

Hand holding a white UK plug while a green-handled screwdriver tightens the strain-relief screws on the flex sheath
The two strain relief screws must be tightened to secure the flex. Make sure you tighten it on the outer sheath, not the inner cores.
© Eugene Brennan

How to Check the Fuse in a Plug

You can check whether the fuse in a plug is ok using a multimeter set to the continuity range. In fact, it's a good idea to have one of these in your home toolkit if you do any basic DIY. Check out my guide to using a multimeter here:

How to Use a Digital Multimeter to Measure Current, Voltage and Resistance.

For more information on electricity and an explanation of volts, amps and watts, see my guide:

How to Understand Electricity: Volts, Amps, Watts and Electrical Appliances

References

How to wire a plug. Plugtest (n.d.). Retrieved November 27, 2022, from https://www.pat-testing-training.net/articles/wiring-plugs.php

BS 1362 Fuse Operation Characteristics. Plugtest (n.d.). Retrieved November 28, 2022, from https://www.pat-testing-training.net/articles/fuse-operation-characteristics.php

Jackson, A., & Day, D. (1993). Collins Complete Diy Manual. HarperCollins.

Disclaimer 

This article is accurate and true to the best of the author’s knowledge. Content is for informational or entertainment purposes only and does not substitute for personal counsel or professional advice in business, financial, legal, or technical matters.

Questions & Answers

Question: A building is being supplied with power at 220v. The load consists of 300 lamps of 60w each and 100 fans of 40w each find (i) the total loads in kilowatts (ii) the current taken by the load ?

Answer: (i) The total load is 300 x 60 + 100 x 40 = 22,000 watts or 22 kW

(ii) To find the current, divide the load in watts by the voltage

So

Current is 22,000 / 220 = 100 amps

There are lots more examples like this on my other article here:

How to Understand Electricity: Volts, Amps and Watts Explained on Appliances

© 2014 Eugene Brennan

Comments

Pepenaldo panana on June 23, 2020:

what i wanted thanks

Gift on May 14, 2020:

Thanks

kudzaiishe on October 16, 2017:

tank you just what i needed

Friday, 6 November 2026

Which Battery Is Best? Choosing Between Alkaline, Zinc, Lithium-Ion and Lead-Acid

Assorted AA and AAA alkaline batteries from brands including Kodak, Maxell, Panasonic, and Tronic scattered on a white surface
AA batteries
© Eugene Brennan

What Type of Battery Should You Choose?

There are various types of batteries on the market today: different sizes, different technology, different voltages, rechargeable and single-use disposables. So how do you know which to use? This article gives some basic facts about the different types of batteries available.

Wednesday, 4 November 2026

High Electricity Bills? These Appliances Are the Most Expensive to Run

Graphic with the words “How to Save Electricity” above euro, pound and dollar symbols
© Eugene Brennan

How Much Does Electricity Cost?

With the cost of electricity rising all the time, it's useful to know how the various appliances in the home are contributing to the cost of your electricity bill.

In this short article, I give a comprehensive list of appliances and an estimate of the cost of running them. The power used by an appliance can differ somewhat from the values quoted but these are typical values. The cost per hour is based on a price of 18c per unit, the current average price in the US, but you can scale up depending on what your electricity supply company charges you.
For more detailed info about electricity, covering volts, watts, amps etc, see my article:

How to Understand Electricity: Volts, Amps and Watts Explained on Appliances.

Electricity Cost Equation

Simply divide watts by 1000 to convert to kilowatt (kW), multiply the cost by the cost per unit, and the result is in cents (or whatever your currency is) 

Cost of Running an Appliance

Cost = Power in kW x Run Time in Hours x Cost per Unit

Example

To work out the cost of running an appliance, we use this equation:

Cost = (Power in watts / 1000) x (cost per unit in cents) x time in hours

E.g. An electric heater with a 2000-watt rating is switched on for 2 hours. If electricity costs 10 c per unit, how much does it cost to power the appliance for this period?

Power in watts = 2000

Cost per unit = 18c

Time in hours = 2

Cost = (Power in watts / 1000) x (cost per unit in cents) x time in hours

= (2000 / 1000) x 18 x 2 = 72 cents

The heater is rated at 2000 watts. This means it uses 2000/1000 = 2 units or kilowatt hours (kWh) in 1 hour. If it was switched on for 15 minutes, it would have used 2000/1000 x 0.25 = 1/2 a kWh. So basically you just need to work out the power in kilowatts by dividing the power in watts by 1000 and then multiply the result by the number of hours followed by the the cost per kWh in cents (or whatever your local currency is)

What is a Kilowatt Hour Meter or Electricity Meter?

The utility company that supplies you with electricity keeps track of your energy usage using a kilowatt hour meter, fitted inside your home or on the wall outside. This meter measures voltage, current and time and displays the result in units or kWh on a mechanical counter display. Electromechanical meters are being replaced by electronic smartmeters which can take into account different tariffs such as night, day and peak rates. They also send the results over the cellular network so they don't have to be read by the "meter man" or consumer.

Kilowatt Hour Meter

Siemens electromechanical electricity meter showing its kilowatt-hour reading
An electromechanical kilowatt-hour meter
© Eugene Brennan

How Do I Know the Wattage of an Appliance?

The voltage, wattage and possibly the current will be specified on the appliance. This information may be embossed into the casing or printed on a label/metal panel. Sometimes this label is located at the back of the appliance e.g. on TVs, washing machines, freezers or other white goods. On kettles, food processors, etc, this information may be printed on the underside.

Information Labels on Appliances

Rating plates on four electrical appliances showing their voltage, current and power consumption
Typical electrical appliance labels/panels
© Eugene Brennan

Which Appliances Use The Most Power?

Air conditioning, electric showers, clothes driers (tumble driers), room heaters and water heaters (immersion heaters) are the most energy hungry appliances. Kettles are also high powered appliances, however since they are turned on for a relatively short period of time, the overall energy cost isn’t too high.

The Most Common Appliances in the Home and the Cost of Running Them (Assuming average cost of 18c per unit in the US)

Table 1. Running costs of appliances
AppliancePower in wattCost per hour in centsNotes on cost
Kitchen range/cooker2000 to 600036 to 108Depending on number of hotplates and whether oven is switched on
Tumble drier250045
Washing machine1000 on average18
Fridge601.08Depends on ambient temperature
Freezer801.44Depends on ambient temperature and capacity of freezer
Kettle2000 to 300036 to 54
Food processor500 to 15009 to 27
Laptop250.45
Desktop computer1001.8Cost is less with LCD monitor
Large TV CRT100 to 1501.8 to 2.7
Large TV Plasma200 to 3003.6 to 5.4
Large TV LCD100 to 2001.8 to 3.6
Large TV LED801.44
Alarm system200.36
HiFi300.54
Transistor radio40.072
Hair drier150027
Microwave oven120021.6
Air conditioning500090Depends on temperature setting on unit
Broadband internet router/modem140.252
100 watt light bulb1001.8
Cordless phone<1w<0.018
Computer printer120.216
Toaster100018
Water tank heater300054
Electric shower7000 to 10000126 to 180
Phone charger5 to 10 W0.09 to 0.18

Work Out Costs Yourself

Electricity Running Cost Calculator

Power unit
Energy consumed:
Estimated running cost:
This calculator assumes the appliance operates continuously at its stated power rating.

What is Vampire Power or Phantom Power?

Many devices draw so called vampire power when on standby. These include sound systems, TVs, HiFis, video and DVD players/recorders, computers, radios etc. Power drawn on standby can be up to 25% of that when fully turned on. If you want to save money – pull the plug.

What is a Power Consumption Monitor?

A power monitor is a useful device for tracking electricity usage and helping you save energy. The monitor is plugged into a wall socket and then the appliance is plugged into the adapter. The device then displays power consumption in watts and tracks energy use in kWh over time. It can also display voltage, current and length of time the appliance is powered on. This is useful for checking the duty cycle or percentage on time for devices that cycle on and off (e.g. fridges, freezers and air conditioners). You can read more about them in this guide:

Checking Power Consumption of Appliances With an Energy Monitoring Adapter

Plug-in electricity power monitor with LCD display and function buttons
Power monitoring adapter
© Eugene Brennan

The Kill a Watt energy usage monitor from Amazon is a basic unit that monitors voltage, amps, watts, kWh and time run. It’s easy to use and each parameter can be selected by simply pressing a dedicated button. Values are displayed on a clear easy-to-read LCD display. Note that this is designed for AC 115 volt appliances.

Kill A Watt P3 electricity usage meter displaying 120.3 volts
Amazon
Kill A Watt electricity meter with a large digital display and buttons for selecting electrical measurements
Amazon

Disclaimer 

This article is accurate and true to the best of the author’s knowledge. Content is for informational or entertainment purposes only and does not substitute for personal counsel or professional advice in business, financial, legal, or technical matters.

© 2012 Eugene Brennan

Comments

khtanned on February 22, 2020:

I would like to get this power meter. May I know the brand or manufacturer.

Thanks

Eugene Brennan (author) from Ireland on February 23, 2020:

Hi khtanned,

This is a B&Q brand power adapter, so only available in the UK and Ireland.What style of plug (country) do you need on the meter?

 K N S Prasad on December 26, 2017:

Very nice for explaining thanks so much.

Delores Wiley on March 13, 2017:

thank you very much I could not read a lot of my appliance wattage and this is very helpful

Checking Power Consumption of Appliances With an Energy Monitoring Adapter

White energy monitoring adapter held in a hand outdoors against green foliage, showing UK-style three-pin socket, LCD screen and control buttons
© Eugene Brennan

How to Measure Power

With the cost of electricity on the increase, an energy monitoring adapter is a useful device that can measure and track the energy consumption of your home appliances.

Sunday, 1 November 2026

What Is a GFCI (RCD)? 7 Tips to Prevent Electric Shock at Home

A GFCI or RCD adapter plugged into an outdoor electrical outlet to prevent electrical shocks
A GFCI or RCD (Residual Current Device) will help prevent potentially dangerous “electrical leaks”.
© Eugene Brennan

What Is a GFCI or RCD, and Why Do I Need One?

A GFCI or “Ground-Fault Circuit Interrupter” is an electrical safety device that shuts off power when there’s an electrical “leak”, increasing your safety by helping to prevent dangerous electrical shocks. A GFCI can typically be plugged into a standard socket outlet.

Wednesday, 22 January 2020

Repairing a Heat Selection Knob on a Fan Heater

Well this was frustrating! The range selection knob on my fan heater was turning without doing anything. I decided to try and open the case to see what was wrong, but of course the manufacturer had used security fixings, relatively uncommon triangular ones too!

Wednesday, 7 December 2016

What Does the Voltage Rating of a Fuse Mean?

Image Courtesy, mtself CC BY SA 3.0 via Wikimedia Commons
The current rating of a fuse specifies the current which the fuse will carry without blowing. Once the current exceeds this value, the fuse will eventually blow. The characteristic of a fuse is such that if the current in a circuit is moderately higher than the fuse rating due to an overload, the fuse will take some time to blow, possibly seconds, minutes or tens of minutes, depending on the magnitude of the overload. If the current is a lot higher e.g. in the case of a short circuit, the fuse will blow in a few tens of milliseconds. While a low voltage or high voltage fuse will blow when the current exceeds the current rating, the current flow in a mains powered circuit can be extremely high (possibly thousands of amps) in a short circuit scenario because the current is coming from a large transformer outside the home. The breaking capacity of a fuse is specified in joules or kiloamps and a mains fuse could have a rating of 10000 amps or more. This is the maximum current the fuse can carry without rupturing. Usually fuses for mains equipment or distribution circuits have a ceramic body to withstand the heat and shock when the fuse blows. The fuse is also filled with quartz sand to absorb the heat and shock and quench the arc when the fuse blows. A glass fuse could simply rupture and possibly cause a fire if it carried such a heavy current. Glass/low voltage fuses may be used on the secondary side of the transformer in the power supply of equipment because the current output of the transformer in a short circuit situation is limited.
×

Posts by Category